Normal Liver Tolerance


Partial Liver Tolerance


Whole Liver Tolerance


Review Articles

Hepatocellular Carcinoma Tolerance


Radiation + Chemotherapy


Other

  1. Mean dose to normal liver (MDTNL) of 23 Gy was tolerable.
  2. Tolerable MDTNL could be estimated by MDTNL (Gy) = -1.686 + 0.023 * normal liver volume (cm3).
  3. For cumulative dose–volume histogram (DVH), the tolerable volume percentages would be less than:
Radiation Dose (Gy) Percentage of Whole Liver
V5 86%
V10 68%
V15 59%
V20 49%
V25 35%
V30 28%
V35 25%
V40 20%

Another 2002 article suggested that when the effective liver volume is 1.0 (i.e., whole liver irradiation), the dose with 5% RILD incidence is 24Gy, and dose with 50% RILD incidence is 43Gy. However if the effective liver volume irradiated is 0.5 (ie., half the liver), the 5% RILD incidence occurs at 32Gy. Liang