Pumps & Fans

Articles

Reference

Example ARs/EEMs

Data Collection

Jest about every plant has pumps. Here are the basic things to look for and collect.

1. Pump nameplate information

 - Brand Name
 - Cat. No
 - HP
 - RPM
 - Voltage
 - Max Amperage
 - Line Frequency (either 50Hz or 60Hz
 - Max Flow rate

2. Motor Nameplate information (if it is not a direct drive pump)

 - Brand Name
 - Cat. No
 - HP
 - RPM
 - Voltage
 - Max Amperage
 - Line Frequency (either 50Hz or 60Hz)

3. Fluid being pumped

 - Its viscosity and density (or if they know it its specific gravity)

4. What kind of system the pump is used in 5. Any Abnormal conditions such as a high/low temperature feed to the pump 6. Flow Rate (and how often the pump operates at this flow rate) 7. Gauge Pressure on both sides of the pump (This is often hard to accomplish since very few pumps will have pressure ports on both sides of the pump.) 8. If there are no gauges here is some more information you will need:

Questions to ask plant personnel

After the Audit

Now it is time to put all data together to start writing some ARs.

Pump Efficiency AR

1. Start by inputing your data into PSAT (start, programs, IAC applications, PSAT 2008, PSAT 2008)

 - The first thing to do is to determine what type of pump you have. PSAT has a drop down list of pumps to choose from or you can set a specific optimal efficiency.
 - Enter the RPM of the pump
 - Choose the type of drive (either direct or belt)
 - Leave the Units alone (they should be set to gpm, ft, hp)
 - Change the kinematic viscosity and specific gravity only if the fuild is not water (to calculate specific gravity from density get the density into g/cm^3 and divide by 1g/cm^3 (density of water))
 - Set the fixed specific speed to no unless you know the pump has a fixed specific speed
 - Input the motor information into the next box (if its a direct drive it is the same as the pump information)
 - Enter the operating fraction (the amount of time the pump operates at the load you are looking at)
 - Put the incremental cost in the next box
 - Put the flow rate you got in the field in the next box
 - Click on the head tool button and fill out the boxes based on what you observed in the field (you can select the type of system you have by either selecting a suction and discharge line system or a suction tank and discharge line system)
 - Switch the button that says power to current so you can enter your amperage reading.

2. Now that your data is in PSAT you know how efficient the pump is and whether or not you should write a pump efficiency AR

 - Most pumps will fall in the 60-85% efficiency range when operating properly.
 - Anthing above 65% is exceptionally good and you might want to write up a best practices section instead about how the company has properly scaled their pumps
 - Between 85% and 60% is questionable depending on the type of pump and its application (if your in doubt about what efficiency is normal for your pump talk to Joe)
 - Below 60% is not good except for low rpm pumps which may only have an efficiency of 25%-35% (talk to Joe if you are in this range). This is the range at which changing pumps becomes feasible.

3. here are some common recommendations for pump efficiency AR

 - Replace pump (only a good solution if your pump is really inefficient (really over sized) because pumps are really expensive and the payback time is very long)
 - Trim Impeller, Smaller impeller (good for over sized pumps that run most of the time at a certain flow rate)
 - Install a VSD (good for pumps with throttle controls or bypass valves that run at several different flow-rates)

Install Controls/Turn off Pump AR

1. Identify any time when the pump(s) may be running that they may not be needed. This might be a pump running continuously when it is only needed for certain parts of batch processes. It also might be a pump running all the time when it is only needed during certain operating hours. 2. Determine if the pump can just be turned off by plant personnel of if some control system needs to be installed.

3. Calculate the electricity being used by the pump when it is not needed to operate. From this and the incremental cost of electricity you can find the cost of operating the pump when it is not needed. This is you cost savings. 4. If this is a pump that can just be turned off by plant personnel you are done. There is no cost to just having plant personnel turn off the pump when it is not needed. 5. For pumps where some control system needs to be installed you need to calculate the cost of installing the control system.